Column or strut is a compression member the effective length of which exceeds X times the least lateral diamentions where X is
Anonymous Quiz
39%
12
26%
6
33%
3
3%
9
👍4
Under uniaxial loading , the maximum shear stress is ______ times the uniaxial stress
Anonymous Quiz
22%
0.5
23%
2
51%
1.5
4%
3
❤8
If a body is acted upon shear stress on two perpendicular planes , the Plane inclined at 45° are subjected to no ______ stress
Anonymous Quiz
15%
Tensile
27%
Compressive
48%
Shear
11%
Bending
👍4
The ratio of ultimate stress to the permissible stress is called
Anonymous Quiz
62%
Factor of safety
15%
Design factor
14%
Stress factor
10%
Load factor
👍2💯2🎉1
Which one of the following is kern diameter of a circular column of diameter d
Anonymous Quiz
8%
d/2
50%
d/4
25%
d/6
18%
d/8
🔥2
A column that fails essentially by direct Crushing at ultimate load is called
Anonymous Quiz
23%
Euler's column
15%
Long column
59%
Short column
3%
None of the above
👍3
Kern of rectangular columns is having ____ shape
Anonymous Quiz
24%
Rectangular
22%
Square
48%
Diamond
5%
Triangle
🤩4
If the load on a column is increased to a value that on its removal the deflection remains, the load is known as
Anonymous Quiz
8%
Critical load
22%
Crippling load
16%
Buckling load
55%
All the above
👍4❤2
The failure of a column depends upon
Anonymous Quiz
4%
Weight of column
23%
Length of column
64%
Slenderness ratio
9%
Cross sectional area
🎉5
Forwarded from AK Engineering Academy
1) ATP 2024 LIVE BATCH
http://on-app.in/app/oc/459095/ake
2) WCD BMC WRD CIDCO
http://on-app.in/app/oc/41776/ake
3) MIDC 4 ACTS
http://on-app.in/app/oc/462695/ake
Call: 📞 9067051404
Please open Telegram to view this post
VIEW IN TELEGRAM
👍2
Pipe material generally used in India for conveying water is
Anonymous Quiz
5%
Lead
68%
Cast iron
8%
Copper
19%
Wrought iron
👍4❤3
The valve in a pipeline which allows flow in one direction only is called
Anonymous Quiz
33%
Sluice valve
10%
Air valve
50%
Reflux valve
6%
Scour valve
👍5💯3❤2
Ferrule is one of the important appurtenances installed in
Anonymous Quiz
19%
Combined sewerage system
48%
Water distribution system
25%
House drainge system
8%
Storm sewerage system
❤5
The equation used commonly for the design of distributing system for water supply is designed by
Anonymous Quiz
16%
Darcys
36%
Mannings
11%
Kutter
37%
Hazen and Williams
👍3❤1
Water demand for a town of given population is function of
Anonymous Quiz
40%
Standard of living
29%
Size of the town
21%
Distance of the water source
10%
Type of water source
🔥3👍2
From high level water resources, the water supply system used in termed as
Anonymous Quiz
30%
Pumping and storage system
18%
Pumping system
49%
Gravity system
3%
Dual system
💯3
Pressure reducing valve is actuated by the fluid Pressure at
Anonymous Quiz
26%
Upstream
44%
Downstream
25%
Within the valve
5%
Drain line
🤩3👍1
Check valve allows the fluid flow
Anonymous Quiz
48%
Only in one direction
27%
In both the direction
20%
To change the direction
6%
To stop
The suitable layout for a water supply distribution system for a city of roads of rectangular pattern is
Anonymous Quiz
11%
Dead end system
72%
Grid Iron system
9%
Ring system
8%
Radial system
💯3
Which of the following is not a layout system for water distribution
Anonymous Quiz
5%
Radial
16%
Dead end
10%
Circular
69%
Cascading
👍3🔥2