Someone in the chat just mentioned something out "balanced neutral" , so I'm going to do a brain dump....
In the US wiring standard we have Leg1 (120v), Neutral (0v) and Leg2(120v). Ideally, the neutral makes sure that your 120v devices get 120v relative to the center point.
What if that center point is missing? Let's disconnect the neutral back to the pole transformer and play along... Imagine you plug a 120v toaster into leg 1 and a 120v coffee maker into leg 2. Since both devices pull about 1200watts, even if the neutral is missing you'll get 240v split evenly between the two devices. if we add another coffee pot, L2 voltage will drop to 80v and the leg with the toaster will rise to 160v. They both still add to 240v but they are "imbalanced" relative to the neutral.
If you have lights that dim or brighten when you run the hair dryer or microwave, look for a loose neutral connection in your load center. The clue is that 120v changes but the 240v stays the same when things are switched on/off.
In the US wiring standard we have Leg1 (120v), Neutral (0v) and Leg2(120v). Ideally, the neutral makes sure that your 120v devices get 120v relative to the center point.
What if that center point is missing? Let's disconnect the neutral back to the pole transformer and play along... Imagine you plug a 120v toaster into leg 1 and a 120v coffee maker into leg 2. Since both devices pull about 1200watts, even if the neutral is missing you'll get 240v split evenly between the two devices. if we add another coffee pot, L2 voltage will drop to 80v and the leg with the toaster will rise to 160v. They both still add to 240v but they are "imbalanced" relative to the neutral.
If you have lights that dim or brighten when you run the hair dryer or microwave, look for a loose neutral connection in your load center. The clue is that 120v changes but the 240v stays the same when things are switched on/off.
π4β€1
Forwarded from USDA PRIME MEMES
This media is not supported in your browser
VIEW IN TELEGRAM
Friends don't let friends carry sigs
π―16β€1π₯΄1
If any one wants to know what I need for Christmas.... https://mechmaxx.com/products/round-hay-baler-silage-machine-30-inch-width-20-inch-diameter
MechMaxx
3-Point PTO Mini Round Hay Baler With Twine Wrap, 20" Diameter x 28" Width Bales, For 15-50hp Tractor, HB3120
Tractor Power Required 15-50 Hp Minimum Tractor Weight 1500 lbs Bale Size οΌDiameter X WidthοΌ Ο20 X 28 in Bale Weight 30 - 50 lbs Overall (L x W x H) 45 x 51 x 47 in Pickup Width 31.5 in Efficiency 1.24-3.11 mi/h Capacity 80 - 100 Bales / Hour Bale Wrappingβ¦
β€7π₯3π1
kinda neat... I'm sending messages to another mesher in Florence. Meshcore sent it the first time as a flood packet (ping pong off anything and every thing). Once I got an ACK from him, we had a path discovered.
I got ACKs that say each message was delivered.
I got ACKs that say each message was delivered.
β€6π₯4
Solar patio light used to make mesh repeaters is $5
https://www.lowes.com/pd/Harbor-Breeze-60-Lumens-1-Watt-Black-Warm-White-Solar-LED-Spot-light/5018244381
https://www.lowes.com/pd/Harbor-Breeze-60-Lumens-1-Watt-Black-Warm-White-Solar-LED-Spot-light/5018244381
π5
This is the motherlode of ICF training. Watch the first, skip the next two and it gets detailed quickly. https://www.youtube.com/watch?v=DFYktAiOSF0&list=PLMFDU7ZHdfWpq4Nul1yohz3koxVQwKui8
YouTube
BuildBlock ICF Installer Training Series: 01. Introduction
Welcome to the BuildBlock ICF Installer Training series.
In this brief introduction, we'll discuss the basic components of ICFs, possible design options, how ICFs are designed and made, and why ICFs are approved as building method in the North American buildingβ¦
In this brief introduction, we'll discuss the basic components of ICFs, possible design options, how ICFs are designed and made, and why ICFs are approved as building method in the North American buildingβ¦
π1
If you are going to order a 32kwh battery, be aware of three things:
1)It MUST use MB56 cells. Several manufacturers are placing two 314ah cells in parallel to make the capacity. This is NOT good engineering practice.
2)You might calculate that you need 32kwh and think you can buy one battery but that battery may be limited to 200amps. If you need 12kw out of your inverter, you will need 250amps and will fall short. In order to get 12kw you will likely need two of any battery.
3)There are many good deals on batteries that do not use JK BMS. If you get one of these you may have vendor lockin when it is time to add more. JK BMS is the universal standard. Vendor A battery will communicate with Vendor B as long as they use JKBMS.
1)It MUST use MB56 cells. Several manufacturers are placing two 314ah cells in parallel to make the capacity. This is NOT good engineering practice.
2)You might calculate that you need 32kwh and think you can buy one battery but that battery may be limited to 200amps. If you need 12kw out of your inverter, you will need 250amps and will fall short. In order to get 12kw you will likely need two of any battery.
3)There are many good deals on batteries that do not use JK BMS. If you get one of these you may have vendor lockin when it is time to add more. JK BMS is the universal standard. Vendor A battery will communicate with Vendor B as long as they use JKBMS.
π5β‘2π2
Off The Grid
If you are going to order a 32kwh battery, be aware of three things: 1)It MUST use MB56 cells. Several manufacturers are placing two 314ah cells in parallel to make the capacity. This is NOT good engineering practice. 2)You might calculate that you needβ¦
To follow up from my previous post... here is a picture of a 48kwh Panda battery. it has three 314ah cells in parallel with no fusing between cells. If one cell were to short out, the other 2 peers would dump amps into it and likely make a lot of heat. This is poor engineering practice. The 32kwh panda is the same it just uses two 314ah cells the same way.
For comparison here's a picture of a yixaing 32kwh battery with individual MB56 cells. Much better, much safer.
For comparison here's a picture of a yixaing 32kwh battery with individual MB56 cells. Much better, much safer.
π―3
Brain dump.... when connecting power sources in parallel you should fuse each power source individually. That way if something goes horribly wrong the malfunctioning unit can pop it's own fuse.
Telsa car batteries consist of 7700 individual 18650 or 2170 cells. Each one is connected to it's peers with a 5 amp fuse. If one cell malfunctions it will pop it's own fuse and the rest of the pack continues to operate.
None of the chinese manufacturers are fusing individual LFP 280 or 314 cells. They just strap them together and hope for the best.
Telsa car batteries consist of 7700 individual 18650 or 2170 cells. Each one is connected to it's peers with a 5 amp fuse. If one cell malfunctions it will pop it's own fuse and the rest of the pack continues to operate.
None of the chinese manufacturers are fusing individual LFP 280 or 314 cells. They just strap them together and hope for the best.
π2β‘1π1π€¨1
Moar brain dump. When you connect PV panels in parallel you can get away without fusing two strings. because even if one string of panels shorts out, they are engineered to accept twice as much current as they produce.
Check the label on any panel and you'll find numbers like Isc 13amps , fuse at 30amps. (Isc is amps short circuit, the max amps the panel can ever make).
However when you combine 3 or more strings of panels now you have a situation where one string could malfunction and the two neighbors could dump amps into it. So when you parallel 3 or more sets of panels you must fuse each individual string at the manufacturers spec (ie probably around 30amps).
There are inline fuse holders that have the MC4 connectors or you can use a combiner box with fuses or breakers.
One more tip... do NOT disconnect MC4 connectors while amps are flowing. Use a shutoff switch or power down the MPPT or inverter before taking MC4s apart. If you take them apart under load they will arc. The arc will destroy the contact surface and about 6 months from now your connector will mysteriously melt.
Check the label on any panel and you'll find numbers like Isc 13amps , fuse at 30amps. (Isc is amps short circuit, the max amps the panel can ever make).
However when you combine 3 or more strings of panels now you have a situation where one string could malfunction and the two neighbors could dump amps into it. So when you parallel 3 or more sets of panels you must fuse each individual string at the manufacturers spec (ie probably around 30amps).
There are inline fuse holders that have the MC4 connectors or you can use a combiner box with fuses or breakers.
One more tip... do NOT disconnect MC4 connectors while amps are flowing. Use a shutoff switch or power down the MPPT or inverter before taking MC4s apart. If you take them apart under load they will arc. The arc will destroy the contact surface and about 6 months from now your connector will mysteriously melt.