Automatic water pump control system using two float switches, a contactor, and a motor. It fills two water tanks.
The float switches detect the water levels in each tank. If both tanks are low, the switches close, activating the contactor and turning on the pump.
If either tank is full, its float switch opens, stopping the pump. The MCB provides protection, and the contactor controls the motor automatically based on tank levels.
The float switches detect the water levels in each tank. If both tanks are low, the switches close, activating the contactor and turning on the pump.
If either tank is full, its float switch opens, stopping the pump. The MCB provides protection, and the contactor controls the motor automatically based on tank levels.
Gear up for another Batch on Data Center MEP Design Course
Get yourself updated with the technology and upskill your career with this Job Oriented Course
A comprehensive Design Course on MEP Data Center for Tier 1,2,3&4
Key Points to be Discussed:
✅Liquid Cooling System
✅Electrical System Calculations
✅Tier Diagram - 1,2,3,4
✅Drainage System
✅Gas Suppression System
✅Pre Action System
✅Impact of Chiller vs Liquid Cooling
✅Hydraulic Calculations using ELITE Software
✅HAP Calculations & Heat Load Calculation for DC
Cable Sizing, Voltage Drop, Light Calculation, Duct Sizing, Pipe Sizing etc....
Next Batch starting from 02nd June 2025
Timings - 10:30 PM IST Onwards (4 Days a week)
For all info regarding to Data Center MEP Design Course Fees Structure, Course Contents, Schedule of Classes and Demo Purpose Class. Click here
https://wa.me/message/4CIVNZX4CFFQJ1
Follow our Page for more MEP Insights
https://lnkd.in/g-zqXNDW
Get yourself updated with the technology and upskill your career with this Job Oriented Course
A comprehensive Design Course on MEP Data Center for Tier 1,2,3&4
Key Points to be Discussed:
✅Liquid Cooling System
✅Electrical System Calculations
✅Tier Diagram - 1,2,3,4
✅Drainage System
✅Gas Suppression System
✅Pre Action System
✅Impact of Chiller vs Liquid Cooling
✅Hydraulic Calculations using ELITE Software
✅HAP Calculations & Heat Load Calculation for DC
Cable Sizing, Voltage Drop, Light Calculation, Duct Sizing, Pipe Sizing etc....
Next Batch starting from 02nd June 2025
Timings - 10:30 PM IST Onwards (4 Days a week)
For all info regarding to Data Center MEP Design Course Fees Structure, Course Contents, Schedule of Classes and Demo Purpose Class. Click here
https://wa.me/message/4CIVNZX4CFFQJ1
Follow our Page for more MEP Insights
https://lnkd.in/g-zqXNDW