@ethioengineers1
👉Flexural Strength is the capacity of the concrete
(usually beams) to resist deformation under
bending moment. It is sometimes called Bending
Strength.
.
👉Tensile Strength is the capacity of concrete to resist
tension/stretched tight.
The similarity is that, by definition - They are both
concrete’s capacity in resisting deformation under
loads. But the loads to which they are resisting
are different. 👇👇👇👇👇
Join for more engineering updates via the link below;
@ethioengineers1
👆👆👆👆👆
⚡ አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።
Flexural Strength vs Tensile Strength@ethioengineers1
👉Flexural Strength is the capacity of the concrete
(usually beams) to resist deformation under
bending moment. It is sometimes called Bending
Strength.
.
👉Tensile Strength is the capacity of concrete to resist
tension/stretched tight.
The similarity is that, by definition - They are both
concrete’s capacity in resisting deformation under
loads. But the loads to which they are resisting
are different. 👇👇👇👇👇
Join for more engineering updates via the link below;
@ethioengineers1
👆👆👆👆👆
⚡ አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።
ለተሳካ የከተማ ፕላን መላውን ከተማ እንደ አንድ ነጠላ አካል የሚገጥም እቅድ መኖር አለበት ፡፡ የከተማውን አጠቃላይ ሁኔታ በተቀናጀ ሁኔታ ለማሳካት ይህ አስፈላጊ ነው ፡፡ የከተሞች ልማት ወይም መስፋፋት ረጅም ጊዜ ይወስዳል ፣ ስለሆነም በእቅዱ መሠረት በማንኛውም ጊዜ ዕድገቱ በማንኛውም ጊዜ ቁጥጥር ማድረግ ይጠበቅበታል ፡፡ እንዲህ ዓይነቱ ዕቅድ ‹ማስተር ፕላን› ይባላል ፡፡ ማስተር ፕላን ወይም የልማት ዕቅድ አሁን ያሉትን ሁኔታዎች ለማሻሻል እና የከተማዋን የወደፊት ዕድገት በተቀናጀ ሁኔታ ለመቆጣጠር የታቀዱ የተለያዩ ሀሳቦችን ሰማያዊ እትም ነው። የከተማው የግለሰቦችን ማንነት በመጠበቅ ረገድ እንዲህ ያለ ዕቅድ ተጨባጭና የታሰበ መሆን አለበት ፡፡ የከተሞች ልማት ረጅም ሂደት ስለሆነ እቅዶቹ ጠንካራ መሆን አለባቸው እንጂ በተመሳሳይ ጊዜ በአዲሶቹ የልማት ለውጦች ውስጥ ያሉትን ፍላጎቶች ለማርካት ከጊዜ ወደ ጊዜ ማሻሻያ ማድረግ አለባቸው ፡፡ ማስተር ፕላኑ በአጠቃላይ የከተማዋን የድሮ ሁኔታ ለማሻሻል ይዘጋጃል ነገር ግን ለአዲሶቹ ከተሞች በድቅድቅ መሬት ላይ እንዲታቀፉ እና እንዲገነቡም እንዲሁ አስፈላጊ ነው ፡፡https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w⏩
▶slabs are constructed to provide a flat surface usually horizontal in building floor, roof etc. They may be supported by beam or column.
classifications of slab
➡ .....one way
➡.....two way
.
* one way slab is a reinforced concrete slab which mainly distribute the loads in one direction( only in shorter direction). such a slab are designed by taking a unit width in longer direction.
.
*two way slabs are slab system which supported and distributed loads in its two directions( both longer and shorter direction). In this case reinforcements are also provided in both directions.
.
*The choice between different slab types of either one way or two way slab system is largely dependent on the architectural requirements and magnitude of loads.
.
*The practical two way slabs may includes
1- two way slab on beam
2- flat plates
3- flat slabs
4- waffle slabs
⚡አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።👇👇👇https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
ስለ Slab ▶slabs are constructed to provide a flat surface usually horizontal in building floor, roof etc. They may be supported by beam or column.
classifications of slab
➡ .....one way
➡.....two way
.
* one way slab is a reinforced concrete slab which mainly distribute the loads in one direction( only in shorter direction). such a slab are designed by taking a unit width in longer direction.
.
*two way slabs are slab system which supported and distributed loads in its two directions( both longer and shorter direction). In this case reinforcements are also provided in both directions.
.
*The choice between different slab types of either one way or two way slab system is largely dependent on the architectural requirements and magnitude of loads.
.
*The practical two way slabs may includes
1- two way slab on beam
2- flat plates
3- flat slabs
4- waffle slabs
⚡አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።👇👇👇https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👉
▶️The following are the some of commonly used stones:
(i) Basalt and trap
(ii) Granite
(iii) Sandstone
(iv) Slate
(v) Laterite
(vi) Marble
(vii) Gneiss
(viii) Quartzite.
.
▶️
:
(i) Basalt and Trap:
The structure is medium to fine grained and compact. Their colour varies from dark gray to black. Fractures and joints are common.
*Their weight varies from 18 kN/m3 to 29 kN/m3.
*The compressive strength varies from 200 to 350 N/mm2. *These are igneous rocks.
*They are used as road metals, aggregates for concrete.
*They are also used for rubble masonry works for bridge piers, river walls and dams.
*They are used as pavement.
:
(ii) Granite:
Granites are also igneous rocks. The colour varies from light gray to pink.
*The structure is crystalline, fine to coarse grained. They take polish well.
They are hard durable.
*Specific gravity is from 2.6 to 2.7 and compressive strength is 100 to 250 N/mm2.
*They are used primarily for bridge piers, river walls, and for dams.
*They are used as kerbs and pedestals. The use of granite for monumental and institutional buildings is common. Polished granites are used as table tops, cladding
for columns and wall.
*They are used as coarse aggregates in concrete.
:
(iii) Sandstone:
*These are sedimentary rocks, and hence stratified.
*They consist of quartz and feldspar.
*They are found in various colours like white, grey, red, buff, brown, yellow and even dark gray. The specific gravity varies from 1.85 to 2.7 and compressive strength varies from 20 to 170 N/mm2.
*Its porosity varies from 5 to 25 per cent. Weathering of rocks renders it unsuitable as building stone.
*It is desirable to use sand stones with silica cement for heavy structures, if necessary.
*They are used for masonry work, for dams, bridge piers and river walls.
:
(iv) Slate:
*These are metamorphic rocks. They are composed of quartz, mica and clay minerals.
*The structure is fine grained. They split along the planes of original bedding easily.
*The colour varies from dark gray, greenish gray, purple gray to black.
*The specific gravity is 2.6 to 2.7. Compressive strength varies from 100 to 200 N/mm2.
*They are used as roofing tiles, slabs, pavements etc.
:
(v) Laterite:
*It is a metamorphic rock. It is having porous and sponges structure.
*It contains high percentage of iron oxide. Its colour may be brownish, red, yellow, brown and grey. Its specific gravity is 1.85 and compressive strength varies from 1.9 to 2.3 N/mm2. It can be easily quarried in blocks. With seasoning it gains strength. When used as building stone, its outer surface should be plastered.
:
(vi) Marble:
*This is a metamorphic rock. It can take good polish. It is available in different pleasing colours like white and pink. Its specific gravity is 2.65 and compressive strength is 70–75 N/
mm2. It is used for facing and ornamental works. It is used for columns, flooring, steps etc.
:
(vii) Gneiss:
It is a metamorphic rock. It is having fine to coarse grains. Alternative dark and white bands are common. Light grey, pink, purple, greenish gray and dark grey coloured varieties are available. These stones are not preferred because of deleterious constituents present in it.
*They may be used in minor constructions. However hard varieties may be used for buildings. The specific gravity varies from 2.5 to 3.0 and crushing strength varies from 50 to 200 N/mm2.
:
(viii) Quartzite:
*Quartzites are metamorphic rocks. The structure is fine to coarse grained and often granular and branded. They are available in different colours like white, gray, yellowish.
Quartz is the chief constituent with feldspar and mica in small quantities. The specific gravity varies from 2.55 to 2.65. Crushing strength varies from 50 to 300 N/mm2. They are used as building blocks and slabs. They
are also used as aggregates for concrete.
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Common Building Stones ▶️The following are the some of commonly used stones:
(i) Basalt and trap
(ii) Granite
(iii) Sandstone
(iv) Slate
(v) Laterite
(vi) Marble
(vii) Gneiss
(viii) Quartzite.
.
▶️
Their qualities and uses are explained below::
(i) Basalt and Trap:
The structure is medium to fine grained and compact. Their colour varies from dark gray to black. Fractures and joints are common.
*Their weight varies from 18 kN/m3 to 29 kN/m3.
*The compressive strength varies from 200 to 350 N/mm2. *These are igneous rocks.
*They are used as road metals, aggregates for concrete.
*They are also used for rubble masonry works for bridge piers, river walls and dams.
*They are used as pavement.
:
(ii) Granite:
Granites are also igneous rocks. The colour varies from light gray to pink.
*The structure is crystalline, fine to coarse grained. They take polish well.
They are hard durable.
*Specific gravity is from 2.6 to 2.7 and compressive strength is 100 to 250 N/mm2.
*They are used primarily for bridge piers, river walls, and for dams.
*They are used as kerbs and pedestals. The use of granite for monumental and institutional buildings is common. Polished granites are used as table tops, cladding
for columns and wall.
*They are used as coarse aggregates in concrete.
:
(iii) Sandstone:
*These are sedimentary rocks, and hence stratified.
*They consist of quartz and feldspar.
*They are found in various colours like white, grey, red, buff, brown, yellow and even dark gray. The specific gravity varies from 1.85 to 2.7 and compressive strength varies from 20 to 170 N/mm2.
*Its porosity varies from 5 to 25 per cent. Weathering of rocks renders it unsuitable as building stone.
*It is desirable to use sand stones with silica cement for heavy structures, if necessary.
*They are used for masonry work, for dams, bridge piers and river walls.
:
(iv) Slate:
*These are metamorphic rocks. They are composed of quartz, mica and clay minerals.
*The structure is fine grained. They split along the planes of original bedding easily.
*The colour varies from dark gray, greenish gray, purple gray to black.
*The specific gravity is 2.6 to 2.7. Compressive strength varies from 100 to 200 N/mm2.
*They are used as roofing tiles, slabs, pavements etc.
:
(v) Laterite:
*It is a metamorphic rock. It is having porous and sponges structure.
*It contains high percentage of iron oxide. Its colour may be brownish, red, yellow, brown and grey. Its specific gravity is 1.85 and compressive strength varies from 1.9 to 2.3 N/mm2. It can be easily quarried in blocks. With seasoning it gains strength. When used as building stone, its outer surface should be plastered.
:
(vi) Marble:
*This is a metamorphic rock. It can take good polish. It is available in different pleasing colours like white and pink. Its specific gravity is 2.65 and compressive strength is 70–75 N/
mm2. It is used for facing and ornamental works. It is used for columns, flooring, steps etc.
:
(vii) Gneiss:
It is a metamorphic rock. It is having fine to coarse grains. Alternative dark and white bands are common. Light grey, pink, purple, greenish gray and dark grey coloured varieties are available. These stones are not preferred because of deleterious constituents present in it.
*They may be used in minor constructions. However hard varieties may be used for buildings. The specific gravity varies from 2.5 to 3.0 and crushing strength varies from 50 to 200 N/mm2.
:
(viii) Quartzite:
*Quartzites are metamorphic rocks. The structure is fine to coarse grained and often granular and branded. They are available in different colours like white, gray, yellowish.
Quartz is the chief constituent with feldspar and mica in small quantities. The specific gravity varies from 2.55 to 2.65. Crushing strength varies from 50 to 300 N/mm2. They are used as building blocks and slabs. They
are also used as aggregates for concrete.
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👉
.
➡Grades of concrete are defined by the strength
composition of the concrete, and the minimum strength the concrete should have following 28 of initial construction.
*The grade of concrete is
understood in measurements of MPa, where C stands for compressive strength and the MPa denotes the overal strength.
*Concrete mixes are defined in ascending numb
of 5, starting at 10, and show the compressive
strength of the concrete after 28 days. For inst
C-10 has the strength of 10 newtons, C-15 has t
strength of 15 newtons, C-20 has 20 newtons
strength and so on.
*Different mixes (M) come in various mix proportions of the various ingredients of cement sand and coarse aggregates. For instance, C-20 comes in the respective ratio of 1:2:3
.
*Generally :-👇
▶C-5 used for Lean concreat
.
▶C-10 Used for: Patio slabs, pathways and non structure work
.
▶C-15 Used for: Pavement kerbs and floor blinding(Ground Slab)
.
▶C-20 Used for: Domestic floors and foundations (with the weight of structure will be lighter). *Also go for workshop bases, garages, driveways and into floor slabs.
.
▶C-25 Used for: Construction in all areas. Multi-purpo concrete mix, usually used for foundations.
.
▶C-30 Used for: Pathways and roadways (this is the
lowest grade concrete mix that can be used for purpose).
*More durable than the grades that come before, and thus is much more weather- resistant and can take heavy road traffic.
.
▶C-35 Used for: Commercial structures. This heavy concrete mix is usually used for creating extern walls and slabs, as well as for structural piling.
.
▶C-40 Used for: Commercial construction sites, foundations and beams for structural support a*roads.
*The most durable in this list, C-40 can withstand chemical corrosion also, so is frequently used on farms where slurry could corrode structures, or in septic tanks.https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Understanding Grades of Concrete .
➡Grades of concrete are defined by the strength
composition of the concrete, and the minimum strength the concrete should have following 28 of initial construction.
*The grade of concrete is
understood in measurements of MPa, where C stands for compressive strength and the MPa denotes the overal strength.
*Concrete mixes are defined in ascending numb
of 5, starting at 10, and show the compressive
strength of the concrete after 28 days. For inst
C-10 has the strength of 10 newtons, C-15 has t
strength of 15 newtons, C-20 has 20 newtons
strength and so on.
*Different mixes (M) come in various mix proportions of the various ingredients of cement sand and coarse aggregates. For instance, C-20 comes in the respective ratio of 1:2:3
.
*Generally :-👇
▶C-5 used for Lean concreat
.
▶C-10 Used for: Patio slabs, pathways and non structure work
.
▶C-15 Used for: Pavement kerbs and floor blinding(Ground Slab)
.
▶C-20 Used for: Domestic floors and foundations (with the weight of structure will be lighter). *Also go for workshop bases, garages, driveways and into floor slabs.
.
▶C-25 Used for: Construction in all areas. Multi-purpo concrete mix, usually used for foundations.
.
▶C-30 Used for: Pathways and roadways (this is the
lowest grade concrete mix that can be used for purpose).
*More durable than the grades that come before, and thus is much more weather- resistant and can take heavy road traffic.
.
▶C-35 Used for: Commercial structures. This heavy concrete mix is usually used for creating extern walls and slabs, as well as for structural piling.
.
▶C-40 Used for: Commercial construction sites, foundations and beams for structural support a*roads.
*The most durable in this list, C-40 can withstand chemical corrosion also, so is frequently used on farms where slurry could corrode structures, or in septic tanks.https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👉
.
⚡ኮንክሪት (concrete) ስሙን ያገኘው ከጥንት ሮማኖች ሲሆን
ቃሉም የመጣው ኮንክሪተስ (Concretus) ከሚለው የሮማኖች ቃል ነው የቃል በቃል ትርጉሙ ተያይዞ ማደግ / አንድ ላይ ማደግ የሚለውን ይወክላል።
.
*ኮንክሪት በአለም ላይ በብዛት የምንጠቀመው የግንባታ ቁስ ነው።
ኮንክሪት የሲሚንቶ የአሸዋ እና የጠጠሮች ውህድ ነው ።
የኮንክሪት የእመቃ ጥንካሬ (compressive strength)
ሚለካው በግሬዱ ነው (Grade)። የተለያዩ የኮንክሪት ግሬዶች
አሉ C-5 ፣ C-15 C-25 C-30 ወዘተ የኮንክሪት ግሬድ ማለት
ኮንክሪቱ ከሃያ ስምንት ቀን በኋላ የሚኖረው የእመቃ ጥንካሬ
(compressive strength ) ማለት ነው ለምሳላ C-25 የሆነ
ኮንክሪት ግሬድ ከ28 ቀን በኋላ የሚኖረው የእመቃ ጥንካሬ
25N/mm^2 ይሆናል ማለት ነው የC-30 ግሬድ ደግሞ
ጥንካሬው 30N/mm^2 ነው
.
*ለውሃ ስራዎች ብዙን ግዜ ተመራጩ የኮንክሪት ግሬድ ከ C-30 በላይ ነው
.
*አንዳንድ ግዜ የኮንክሪት ግሬዶች በተለያዩ መፅሃፎች በተለያየ
መልክ ይጠቀሳሉ ለምሳሌ አንዳንድ መፅሃፎች C-30 C-15
የሚለውን አጠቃቀስ ሲጠቀሙ አንዳንዶቹ ደግሞ M-30 M-15
የሚለውን ይጠቀማሉ (ከታች በምስሉ እንደተጠቀሰው) ....በ
«C»የሚጠቀሱ የኮንክሪት ግሬዶች በC መጠቀሳቸው የእመቃ ጥንካሬያቸው የተለካው በሲሊንደሪካል ፍተሻ (CYLINDRICAL test ) ስለሆነ ነው በM የሚጠቀሱት ደግሞ ፍተሻው (test) የተደረገው በኪውቢክ ፍተሻ (cubic test) ስለሆነ ነው። በሁለቱ የፍተሻ አይነቶች የሚደረጉ የኮንክሪት ግሬዶች የእመቃ ጥንካሬአቸው ይለያያል። ሲሊንደሪካል ፍተሻ በአንፃራዊነት የኮንክሪትን ትክክለኛ እምቅ ጥንካሬ ይገልፃል ስለዚህ ከኪውቢክ ፍተሻው የተሻለ ነው ማለት ነው።
.
*ከላይ በኪውቢክ ፍተሻ የተደረገ የተለያዩ የኮንክሪት
ግሬዶች ፣ ያላቸው የሲሚንቶ የአሸዋ እና የጠጠር ምጣኔ (ratio) እና ከ28 ቀን በኋላ የሚያገኙት ጥንካሬ ተገልጿል።
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
ስለ ኮንክሪት እና የኮንክሪት ግሬዶች .
⚡ኮንክሪት (concrete) ስሙን ያገኘው ከጥንት ሮማኖች ሲሆን
ቃሉም የመጣው ኮንክሪተስ (Concretus) ከሚለው የሮማኖች ቃል ነው የቃል በቃል ትርጉሙ ተያይዞ ማደግ / አንድ ላይ ማደግ የሚለውን ይወክላል።
.
*ኮንክሪት በአለም ላይ በብዛት የምንጠቀመው የግንባታ ቁስ ነው።
ኮንክሪት የሲሚንቶ የአሸዋ እና የጠጠሮች ውህድ ነው ።
የኮንክሪት የእመቃ ጥንካሬ (compressive strength)
ሚለካው በግሬዱ ነው (Grade)። የተለያዩ የኮንክሪት ግሬዶች
አሉ C-5 ፣ C-15 C-25 C-30 ወዘተ የኮንክሪት ግሬድ ማለት
ኮንክሪቱ ከሃያ ስምንት ቀን በኋላ የሚኖረው የእመቃ ጥንካሬ
(compressive strength ) ማለት ነው ለምሳላ C-25 የሆነ
ኮንክሪት ግሬድ ከ28 ቀን በኋላ የሚኖረው የእመቃ ጥንካሬ
25N/mm^2 ይሆናል ማለት ነው የC-30 ግሬድ ደግሞ
ጥንካሬው 30N/mm^2 ነው
.
*ለውሃ ስራዎች ብዙን ግዜ ተመራጩ የኮንክሪት ግሬድ ከ C-30 በላይ ነው
.
*አንዳንድ ግዜ የኮንክሪት ግሬዶች በተለያዩ መፅሃፎች በተለያየ
መልክ ይጠቀሳሉ ለምሳሌ አንዳንድ መፅሃፎች C-30 C-15
የሚለውን አጠቃቀስ ሲጠቀሙ አንዳንዶቹ ደግሞ M-30 M-15
የሚለውን ይጠቀማሉ (ከታች በምስሉ እንደተጠቀሰው) ....በ
«C»የሚጠቀሱ የኮንክሪት ግሬዶች በC መጠቀሳቸው የእመቃ ጥንካሬያቸው የተለካው በሲሊንደሪካል ፍተሻ (CYLINDRICAL test ) ስለሆነ ነው በM የሚጠቀሱት ደግሞ ፍተሻው (test) የተደረገው በኪውቢክ ፍተሻ (cubic test) ስለሆነ ነው። በሁለቱ የፍተሻ አይነቶች የሚደረጉ የኮንክሪት ግሬዶች የእመቃ ጥንካሬአቸው ይለያያል። ሲሊንደሪካል ፍተሻ በአንፃራዊነት የኮንክሪትን ትክክለኛ እምቅ ጥንካሬ ይገልፃል ስለዚህ ከኪውቢክ ፍተሻው የተሻለ ነው ማለት ነው።
.
*ከላይ በኪውቢክ ፍተሻ የተደረገ የተለያዩ የኮንክሪት
ግሬዶች ፣ ያላቸው የሲሚንቶ የአሸዋ እና የጠጠር ምጣኔ (ratio) እና ከ28 ቀን በኋላ የሚያገኙት ጥንካሬ ተገልጿል።
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
SETTLEMENT OF FOUNDATIONS (part two )
@ethioengineers1
The vertical downward movement of the base of a structure is calied settlement and its effect upon the structure depends on
its magnitude, its uniformity, the length of the time over which it takes place, and the nature of the structure itself.
.
Foundation settlement may be caused by some or a combination of the following reasons:
1. Elastic compression of the foundation and the underlying soil.
2. Inelastic (or plastic) compression of the undertying soils, which is much larger tban the elastic compression. The
inelastic compression can be predicted by the theory of consolidation.
3. Ground waser lowering. Repeated lowering and raising of water level in loose granular soil tends to compact the soil and cause settlement of the ground surface. Lowering of water level in fine grained soils cause consolidation settlement.
4. Vibrations due to pile driving, blasting and oscillating machineries may cause settlement in deposits of granular soils.
5. Seasonal swelling and shrinkage of expansive clays.
6. Ground movement on earth slopes , such as surface
erosion, slow creep or landslide.
7. Other causes such as adjacent excavation, mining
subsidence, underground erosion, etc.
.
A certain amount of elastic and inelastic settlement of foundations is unavoidable,and it should be taken into account in design.
Provided the settlement is uniform over the whole area of the building and is not excessive, it does little damage. If, however, the amount of settlement varies at different points under the building, giving rise to what is known as relative or differential settlement, stresses will be set up in the structure.
.
These may be relived in the case of brick structure, for example, by the setting up of a large number of cracks at the joints, but in more rigid structures, overstressing of some structural members might occur. It is suggesed that the allowable pressure should be selected such that the maximum settlement of any individual foundation is 2.5 cm.
It has also been suggested that the differential settlement of uniformly loaded continuous foundation and of equally loaded spread foundations of approximately the same size, is unlikely to exceed half the maximum settlement, and that normal structures such as office buildings and flats can satisfactorily withstand differential settlements of about 18 mm between adjacent columns spaced 6 to 8 m apart. .
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👉
@ethioengineers1
▶️The allowable settlement is defined as the acceptable amount of settlement of the structure and it usually includes a factor of safety.
The allowable settlement depends on many factors, including the following:
*The Type of Construction – For example, wood-frame.
buildings with wood siding would be much more tolerant than unreinforced brick buildings.
*The Use of the Structure – Even small cracks in a house might be considered unacceptable, whereas much larger cracks in an industrial building might not even be noticed.
*The Presence of Sensitive Finishes – Tile or other sensitive finishes are much less tolerant of movements.
*The Rigidity of the Structure – If a footing beneath part of a very rigid structure settles more than the others,the structure will transfer some of the load away from the footing.
However, footings beneath flexible structures must settle much more before any significant load transfer occurs.
Therefore, a rigid structure will have less differential
settlement than a flexible one.
*Aesthetic and Serviceability Requirements – The allowable settlement for most structures, especially buildings, will be governed by aesthetic and serviceability requirements, not
structural requirements.
Unsightly cracks, jamming doors and windows, and other similar problems will develop long before the integrity of the structure is in danger. .https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Allowable settlement (part one)
@ethioengineers1
▶️The allowable settlement is defined as the acceptable amount of settlement of the structure and it usually includes a factor of safety.
The allowable settlement depends on many factors, including the following:
*The Type of Construction – For example, wood-frame.
buildings with wood siding would be much more tolerant than unreinforced brick buildings.
*The Use of the Structure – Even small cracks in a house might be considered unacceptable, whereas much larger cracks in an industrial building might not even be noticed.
*The Presence of Sensitive Finishes – Tile or other sensitive finishes are much less tolerant of movements.
*The Rigidity of the Structure – If a footing beneath part of a very rigid structure settles more than the others,the structure will transfer some of the load away from the footing.
However, footings beneath flexible structures must settle much more before any significant load transfer occurs.
Therefore, a rigid structure will have less differential
settlement than a flexible one.
*Aesthetic and Serviceability Requirements – The allowable settlement for most structures, especially buildings, will be governed by aesthetic and serviceability requirements, not
structural requirements.
Unsightly cracks, jamming doors and windows, and other similar problems will develop long before the integrity of the structure is in danger. .https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
For a successful town planning there must be a plan which envisages the entire town as a single unit. This is necessary to achieve overall development of the town in a coordinated manner. The development or expansion of a town takes a long time, and therefore, the development is required to be controlled at any time on the basis of a plan. Such a plan is called as 'Master Plan'. A master plan or a development plan is thus a blue print of the various proposals that are intended to improve the existing conditions and to control the future growth of the town in a coordinated manner. Such a plan must be realistic, ideal to be aimed at, preserving the individuality of the town. "read before you directly copy man" Since the development of the town is a lengthy process, the plan must not be rigid but elastic at the same time so as to amend it from time to time to satisfy the changing needs in the new developments. The master plan is generally prepared to improve the old conditions of the town but it is also equally necessary for the new cities to be planned and built on virgin land.ለተሳካ የከተማ ፕላን መላውን ከተማ እንደ አንድ ነጠላ አካል የሚገጥም እቅድ መኖር አለበት ፡፡ የከተማውን አጠቃላይ ሁኔታ በተቀናጀ ሁኔታ ለማሳካት ይህ አስፈላጊ ነው ፡፡ የከተሞች ልማት ወይም መስፋፋት ረጅም ጊዜ ይወስዳል ፣ ስለሆነም በእቅዱ መሠረት በማንኛውም ጊዜ ዕድገቱ በማንኛውም ጊዜ ቁጥጥር ማድረግ ይጠበቅበታል ፡፡ እንዲህ ዓይነቱ ዕቅድ ‹ማስተር ፕላን› ይባላል ፡፡ ማስተር ፕላን ወይም የልማት ዕቅድ አሁን ያሉትን ሁኔታዎች ለማሻሻል እና የከተማዋን የወደፊት ዕድገት በተቀናጀ ሁኔታ ለመቆጣጠር የታቀዱ የተለያዩ ሀሳቦችን ሰማያዊ እትም ነው። የከተማው የግለሰቦችን ማንነት በመጠበቅ ረገድ እንዲህ ያለ ዕቅድ ተጨባጭና የታሰበ መሆን አለበት ፡፡ የከተሞች ልማት ረጅም ሂደት ስለሆነ እቅዶቹ ጠንካራ መሆን አለባቸው እንጂ በተመሳሳይ ጊዜ በአዲሶቹ የልማት ለውጦች ውስጥ ያሉትን ፍላጎቶች ለማርካት ከጊዜ ወደ ጊዜ ማሻሻያ ማድረግ አለባቸው ፡፡ ማስተር ፕላኑ በአጠቃላይ የከተማዋን የድሮ ሁኔታ ለማሻሻል ይዘጋጃል ነገር ግን ለአዲሶቹ ከተሞች በድቅድቅ መሬት ላይ እንዲታቀፉ እና እንዲገነቡም እንዲሁ አስፈላጊ ነው ፡፡https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
✅✅
1- Maximum and Minimum Reinforcement Ratio
The minimum reinforcement ratio of 1 % is to be used in tied or spirally reinforced columns. This minimum reinforcement is needed to safeguard against any bending, reduce the effect of shrinkage and creep and enhance the ductility of columns.
2- Minimum Number of Reinforcing Bars
Minimum four bars within rectangular or circular sections; or one bar in each corner of the cross-section for other shapes and a minimum of six bars in spirally reinforced columns should be used.
3- Clear Distance between Reinforcing Bars
For tied or spirally reinforced columns, clear distance between bars should not be less than the larger of 150 times bar diameter or 4 cm.
4- Concrete Protection Cover
The clear concrete cover should not be less than 4 cm for columns not exposed to weather or in contact with the ground. It is essential for protecting the reinforcement from corrosion or fire hazards.
5- Minimum Cross-Sectional Dimensions
For practical considerations, column dimensions can be taken as multiples of 5 cm.
6- Lateral Reinforcement
Ties are effective in restraining the longitudinal bars from buckling out through the surface of the column, holding the reinforcement cage together during the construction process, confining the concrete core and when columns are subjected to horizontal forces, they serve as shear reinforcement. Spirals, on the other hand, serve in addition to these benefits in compensating for the strength loss due to spalling of the outside concrete shell at ultimate column strength
7- Ties
For longitudinal bars, 32 mm or smaller, lateral ties 10 mm in diameter should be used. In some countries, ties of 8 mm dia are used for column construction. .
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Design Of Columns As Per ACI 1- Maximum and Minimum Reinforcement Ratio
The minimum reinforcement ratio of 1 % is to be used in tied or spirally reinforced columns. This minimum reinforcement is needed to safeguard against any bending, reduce the effect of shrinkage and creep and enhance the ductility of columns.
2- Minimum Number of Reinforcing Bars
Minimum four bars within rectangular or circular sections; or one bar in each corner of the cross-section for other shapes and a minimum of six bars in spirally reinforced columns should be used.
3- Clear Distance between Reinforcing Bars
For tied or spirally reinforced columns, clear distance between bars should not be less than the larger of 150 times bar diameter or 4 cm.
4- Concrete Protection Cover
The clear concrete cover should not be less than 4 cm for columns not exposed to weather or in contact with the ground. It is essential for protecting the reinforcement from corrosion or fire hazards.
5- Minimum Cross-Sectional Dimensions
For practical considerations, column dimensions can be taken as multiples of 5 cm.
6- Lateral Reinforcement
Ties are effective in restraining the longitudinal bars from buckling out through the surface of the column, holding the reinforcement cage together during the construction process, confining the concrete core and when columns are subjected to horizontal forces, they serve as shear reinforcement. Spirals, on the other hand, serve in addition to these benefits in compensating for the strength loss due to spalling of the outside concrete shell at ultimate column strength
7- Ties
For longitudinal bars, 32 mm or smaller, lateral ties 10 mm in diameter should be used. In some countries, ties of 8 mm dia are used for column construction. .
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👉
▶️The reinforcement must be fixed with appropriate accuracy in the position specified by the designer to ensure proper structural performance, durability and fire resistance. *Insufficient cover can result in corrosion of the reinforcement, leading to cracking and spalling of the concrete and eventually, if left unchecked, to a reduction in the cross-sectional area of the reinforcement and in the strength of the structure. The cover must also be sufficient to provide the required degree of fire resistance. Too little cover reduces the fire resistance; too much, unless precautionary measures are taken, can make the structure vulnerable to spalling, which again reduces the fi re resistance. Incorrect positioning of the reinforcement can seriously reduce the load-carrying capacity of the structural member.
*Unless otherwise specified, the concrete cover to the reinforcement should be within the following permissible deviations from the dimensions specified in BS 8110:
:
*Bars up to 12 mm diameter: +5mm –5mm
*Bars over 12 mm up to 25 mm: +10 mm –5mm
*Bars over 25 mm: +15 mm –5mm
:
▶️At each end of reinforcing bar, net less that 25 mm or less than twice the diameter of the bar.
*For a longitudinal reinforcing bar in a column, not less than 40 mm not less than the diameter of such bar.
*In case of columns of minimum dimension of 20 cm or under, whose reinforcing bards do no not exceed 12 mm a cover of 25 mm to be used.
*For longitudinal reinforcing bars in a beam, not less than 30 mm or less than the diameter of the bar.
*For tensile, compressive shear or other reinforcements in a slab or wall not less than 15 mm, not less that the diameter of such bar.
*For any other reinforcement not less than 15 mm, not less than the diameter of such bar.
*For footings and other principal structural members in which the concrete is deposited directly against the ground, cover to the bottom reinforcement shall be 75 mm. If concrete is poured on a layer of lean concrete, the bottom cover maybe reduced to 50 mm.
*For concrete surfaces exposed to the weather or the ground after removal of forms, such as retaining walls, grade beams, footing sides and top etc. not less than 50 mm.
*Increased cover thickness shall be provided as indicated on the drawings, for surfaces exposed to the action of harmful chemicals (or exposed to earth contaminated by such chemicals), acid, alkali, saline atmosphere, sulphorone, smoke etc.
*For liquid retaining structures, the minimum cover to all steel shall be 40 mm or the diameter of the main bar, whichever is greater. In the presence of sea water and oils and waters of a corrosive character the covers, shall be increased by 10 mm.
Protection to reinforcement in case of concrete exposed to harmful surroundings may also be given by providing a dense impermeable concrete with approved protective coatings. In such a case the extra cover mentioned in (b) & (i) above may be reduced.
:
▶️The correct cover shall be maintained by cement mortar cubes (blocks) or other approved means. Reinforcements for footings, grade beams and slabs on a sub-grade shall be supported on re-cast concrete blocks as approved by EIC.
*The use of pebbles or stones shall not be permitted.
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Concrete Cover Distance for Reinforcement Bar
▶️The reinforcement must be fixed with appropriate accuracy in the position specified by the designer to ensure proper structural performance, durability and fire resistance. *Insufficient cover can result in corrosion of the reinforcement, leading to cracking and spalling of the concrete and eventually, if left unchecked, to a reduction in the cross-sectional area of the reinforcement and in the strength of the structure. The cover must also be sufficient to provide the required degree of fire resistance. Too little cover reduces the fire resistance; too much, unless precautionary measures are taken, can make the structure vulnerable to spalling, which again reduces the fi re resistance. Incorrect positioning of the reinforcement can seriously reduce the load-carrying capacity of the structural member.
*Unless otherwise specified, the concrete cover to the reinforcement should be within the following permissible deviations from the dimensions specified in BS 8110:
:
*Bars up to 12 mm diameter: +5mm –5mm
*Bars over 12 mm up to 25 mm: +10 mm –5mm
*Bars over 25 mm: +15 mm –5mm
:
▶️At each end of reinforcing bar, net less that 25 mm or less than twice the diameter of the bar.
*For a longitudinal reinforcing bar in a column, not less than 40 mm not less than the diameter of such bar.
*In case of columns of minimum dimension of 20 cm or under, whose reinforcing bards do no not exceed 12 mm a cover of 25 mm to be used.
*For longitudinal reinforcing bars in a beam, not less than 30 mm or less than the diameter of the bar.
*For tensile, compressive shear or other reinforcements in a slab or wall not less than 15 mm, not less that the diameter of such bar.
*For any other reinforcement not less than 15 mm, not less than the diameter of such bar.
*For footings and other principal structural members in which the concrete is deposited directly against the ground, cover to the bottom reinforcement shall be 75 mm. If concrete is poured on a layer of lean concrete, the bottom cover maybe reduced to 50 mm.
*For concrete surfaces exposed to the weather or the ground after removal of forms, such as retaining walls, grade beams, footing sides and top etc. not less than 50 mm.
*Increased cover thickness shall be provided as indicated on the drawings, for surfaces exposed to the action of harmful chemicals (or exposed to earth contaminated by such chemicals), acid, alkali, saline atmosphere, sulphorone, smoke etc.
*For liquid retaining structures, the minimum cover to all steel shall be 40 mm or the diameter of the main bar, whichever is greater. In the presence of sea water and oils and waters of a corrosive character the covers, shall be increased by 10 mm.
Protection to reinforcement in case of concrete exposed to harmful surroundings may also be given by providing a dense impermeable concrete with approved protective coatings. In such a case the extra cover mentioned in (b) & (i) above may be reduced.
:
▶️The correct cover shall be maintained by cement mortar cubes (blocks) or other approved means. Reinforcements for footings, grade beams and slabs on a sub-grade shall be supported on re-cast concrete blocks as approved by EIC.
*The use of pebbles or stones shall not be permitted.
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Why is the bending?This is called a joggle in technical term.
The bent is provided to overlap the column reinforcement and to keep in alignment in its dimension (column size )..... if we don’t bend the reinforcement at overlapping then the size of the column will increase when we go up.
So the point is TO MINIMIZE LOAD IN THE TOP AND TO REDUCE THE SIZE OF COLUMN ON THE WAY
.
⚡አሁኑኑ Join በማረግ እና ለጓደኛዎ እና ለሚያቁት ሁሉ ሼር ያድርጉ።https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
▶️Definitions of terms Of Masonry👇 (part one)
.1. Course : A course is a horizontal layer of bricks stones
2. Bed : the surface of a stone perpendicular to the line of pressure of (lower surface of bricks or stones in each course)
3. Back : The inner surface of wall not exposed is called back.
The material forming back is known as backing
4. Face : The exterior of the wall exposed to weather is known
as face. The material used in the facing of wall is known as
facing
5. Hearting : It is the interior portion of a wall between facing
and backing
6. Head : It is a brick or stone, which lies with its greatest length at right angles to the face of the work.
7. Stretcher : It is a brick or a stone which lies with its congest
side parallel to the face of the work
8. Bond : The method of arranging bricks so that the individual units are tied together
9. Spalls : The chips of stones used for filling the interstices in
stone masonry
10. Quoins : The stones used for the corners of walls of structure
11. Bat : It is a portion of a brick cut across the width.
12. Closer: It is the portion of a brickcut in such a manner that its one long face remains uncut
13. Queen closer: it is the portion of a brick obtained by cutting a brick length-wise into two portions
14. King closer: It is the portion of brick obtained by cutting off
the triangular piece between the centre of one end and the
centre of one side.
15. Bevelled closer: It is the portion of a brick in which the
whole length of the brick is bevelled for maintaining half
width at one end and full width at the other
16. Frog : It is an indentation or depression on the top face of a
brick made with the object of forming a key for the mortar.
17. Sill : It is a horizontal stone, concrete or wood, employed for
the purpose of shedding off rain water from the face of wall
immediately below the window opening
18. Corbel : It is the extension of one or more course of stone or
brick from the face of a wall to serve as a support for wall
plates
19. Templates : Pieces of stones placed under the end of a beam
to distribute load over a greater area.
20. Coping : It is the course placed upon the exposed top of an external wall to prevent the seepage of water
21. Buttress : It is a sloping or stepped masonry projection from a tall wall intended to strengthen the wall against the thrust of a roof
.
#BuildingConstruction
#Masonary
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
👍1
Stone masonry ( part two )👉 The construction of stones bonded together with mortar is termed as stone masonry
🔸 Different types of stones
used for different purposes
1. Heavy engineering works : Granite, gneiss
2. Buildings situated in industrial towns :- Granite and compact sandstone
3. Pavements, railway ballast, doorsits and steps :- Granite slabs and slate
4. Electrical switch board :- Marble slabs and slate
5. Fire resistance works :- Compact sandstone
6. Carving and ornamental works :- Marble and laterite
7. Face work and architectural purposes :- Marble, granite closer gained sand stone
https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
DIFFERENT TYPES OF DEFECTS FOUND ON BRICKS.1. BLOATING
This defect observed as spongy swollen mass over the surface of burned bricks. This is caused due to the presence of excess carbonaceous matter and sulphur in brick-clay.
2. CHUFFS
The deformation of the shape of bricks caused by the rain water falling on hot bricks is known as chuffs.
3. SPOTS
Iron sulphide, if present in the brick clay, results in dark surface spots on the brick surfaces. Such bricks though not harmful are unsuitable for exposed masonry work.
4. BLISTERS
Broken blisters are generally caused on the surface of sewer pipes and drain tiles due to air imprisoned during their moulding.
5. LAMINATIONS
These are caused by the entrapped air in the voids of clay. Laminations produce thin lamina on the brick faces which weather out on exposure.https://t.me/joinchat/AAAAAEo_NBVYFBTZCKpA4w
Forwarded from SMH General Construction
ደረጃ(Stair case)1.step እርምጃ-ወደ ላይ ሲወርድ / ሲወርድ እግሩ የሚቀመጥበት የደረጃ ክፍል ፡፡
2. tread - የደረጃው አግድም ክፍል።
3. Riser-የደረጃ አንድ ቀጥ ያለ ክፍል ፡፡
4. String
-ደረጃዎቹን የሚደግፍ ዝንባሌ ያለው አባል ፡፡
5. Landing-በእያንዳንዱ በረራ መጨረሻ ላይ የቀረበው አግድም መድረክ ነው ፡፡
6. pitch(ማስገቢያ) - የደረጃው ቁመት ነው ፡፡
7. Hand railing-እጅን የሚደግፍ ደረጃ ያለው አዝማሚያ አባል ነው ፡፡
8. መውጣት እና መውረድ፡፡፡ ፡፡
9. balster- የ hand rail መደገፍያ ቀጥ ያለ መካከለኛ ድጋፍ ነው ፡፡
a good stair chxs
የሚከተሉት ጥሩ ደረጃ ባህሪዎች ናቸው ፡
10. ከህንፃው ከሁሉም ጎኖች በቀላሉ መድረስ አለበት
11. አየር መኖር አለበት
12. በእያንዳንዱ flight መጨረሻ ሰፊ landing ሊኖረው ይገባል
13. በመደበኛነት flight ውስጥ ከ 12 ደረጃዎች በላይ መሆን የለበትም።
14. የደረጃዎቹ መነሳት እና መሄዳቸው የተመጣጠነ መሆን ያለበት እና የflight መውጣት እና መውረድ ቀላል ነው ፡፡
15. የእጅ ጣውላ ቢያንስ በደረጃው በአንዱ በኩል መሰጠት አለበት
16. የደረጃው angle ከ 30 እስከ 45 ዲግሪዎች መሆን አለበት ፡፡
Stair types
Straight stairs
Quarter-turn stairs
Dog-legged stairs
Open-newel stairs
Circular stairs
Bifurcated stairs
Geometrical stairs
Spiral stairs
ደረጃዎች
ደረጃዎች ከሚከተሉት ማናቸውም ቁሳቁሶች ይገነባሉ ፡፡
የጡብ ማሳዎች ፣ የድንጋይ ንጣፍ ፣ ጣውላዎች ፣ ብረት ፣ የተጠናከረ የሲሚንቶ ኮንክሪት